June 5, 2000 Man ual Rev 1 .0 5.13
Value:
Standard Numeric
Meaning:
The stopping time of the press in milliseconds the last time it stopped.
Section 5.7.29 Parameter 029 - Last Stop Position
Value:
Standard Numeric
Meaning:
0 = Did not stop at top.
1 = Stopped at top.
Section 5.7.30 Parameter 030 - Last Start Time
Value:
Standard Numeric
Meaning:
The starting time in milliseconds the last time the clutch was engaged.
Section 5.7.35 Parameter 035 - Peak Forward Tonnage (Channel 1)
Value:
Standard Numeric, 1 decimal place
Meaning:
The peak forward tonnage registered on this channel for the last hit. This value is in .1 tons. If
“Send Decimal Point” is “No” then the PLC must assume a decimal place of 1. For example:
12.3 tons will be sent as 123
25 tons will be sent as 250
Note that this is true even if the tonnage monitor itself does not show a decimal point on its screen.
Section 5.7.36 Parameter 036 - Peak Forward Tonnage (Channel 2)
Value: